Sump Systems
Reviewed by a working tradesman with 17+ years in the field.
Some links on this site are affiliate links. If you buy through them we may earn a commission at no extra cost to you. Affiliate disclosure
A sump pumps away foundation drain water when gravity cannot. It is a mechanical system, so plan for failure.
Tap your level and the boxes below open to the advice for you. Remembered on this device.
By the end you can
- Say what Part 9 requires of a sump pit and cover.
- Choose pump type and work out a rough size from flow and head.
- Fit a check valve and discharge line that can be serviced.
- Test and maintain the system, and plan for a power failure.
Pumps run on electricity near water. Leave the wiring to a licensed electrician, who works to the Canadian Electrical Code and your provincial rules. Never handle a pump or cord standing in water. Cutting the slab makes silica dust, so wet-cut or use dust extraction and wear a fit-tested respirator. Keep the pit covered, because an open pit is a fall and child hazard.
The big idea
A sump collects water from the foundation drain and pumps it away when gravity cannot. It is a mechanical system with a pump, a switch and a power supply, so it can fail. Design for that.
What the code says
From Part 9, Section 9.14, as printed in the Vancouver Building Bylaw 2014:
- The pit is at least 750 mm (2 ft 5 1/2 in) deep and at least 0.25 m² (2.7 ft²) in area (9.14.5.2).
- It has a cover that resists removal by children and is airtight (9.14.5.2, with 9.25.3.3).
- Where gravity drainage is not practical, an automatic sump pump discharges to a sewer, a drainage ditch or a dry well (9.14.5.2).
- Where a stone layer is used instead of pipe, the excavation is graded so the whole layer drains to a sump (9.14.4.3).
A 0.25 m² pit is about 500 mm (20 in) square, or 565 mm (22 1/4 in) round. The text I read sets no pump size, alarm or backup. Those are good practice, so confirm what your province requires.
Pump circuits fall under the Canadian Electrical Code and your provincial electrical rules, so hire a licensed electrician and ask what protection your jurisdiction requires. An airtight sump cover also helps keep radon out. Part 9 asks for a sub-slab depressurization rough-in in dwellings (9.13.4.2), with exemptions. Confirm what your province requires.
The pit
- Set it at the lowest point of the drain system.
- Size it to the code and the pump maker. A retailer's guide suggests an 18 to 24 in (450 to 600 mm) pit, to reduce short cycling.
- A liner on a stone base, with a watertight drain connection and a sealed cover.
- Leave a gravel and sediment space below the pump, so silt does not foul the float.
Pump types
- Submersible: quiet and efficient, and common in houses.
- Pedestal: the motor sits above the water, which is easier to service but noisier.
- Backup pump: battery or water-powered, for power outages.
- Two pumps: for high water tables or critical basements.
Sizing
Size by flow and head, not by horsepower. A bigger pump is not always better, because an oversized pump short-cycles and wears its switch, and an undersized one runs continuously.
- Flow: pit volume per cycle times cycles per minute in a storm.
- Head: the vertical lift from the pit to the highest point of the discharge, plus friction. A retailer's guide uses 1 ft of head per 10 ft of horizontal pipe, plus 1 to 2 ft per pair of elbows. That is a rule of thumb.
- Pump curve: read the maker's curve at your head, with about 25 percent margin. Box ratings are at zero lift and overstate real flow.
Example. A 560 mm (22 in) pit has 0.25 m² of area. With the float switching on 200 mm (8 in) above where it switches off, each cycle moves 0.25 × 0.2 = 0.05 m³, or 50 L (13 US gal). If it cycles every 2 minutes in a storm, the flow is 25 L/min (6.6 US gal/min), so look for about 31 L/min with a 25 percent margin. With 2.4 m (7 ft 10 in) of lift and 12 m (39 ft 4 in) of horizontal pipe, the head is about 2.4 + 1.2 = 3.6 m (11 ft 10 in). Every number here is made up.
Discharge and check valve
- Rigid discharge pipe, with a check valve above the pump so water does not run back. One municipal checklist says to confirm there is a check valve on the drain line just above the sump cover.
- A union or serviceable fitting, so the pump can be removed.
- Where freezing is a risk, follow the pump maker's advice on a relief hole.
- The discharge goes to a sewer, ditch or dry well (9.14.5.2). The Discharge Lines page covers where the water goes.
Backup, alarm and maintenance
- A high-water alarm, and a battery or water-powered backup pump, are good practice. Power outages come with storms.
- A municipal checklist says to test at least twice a year, preferably before spring thaw. Pour water in the pit and check that the float moves freely, the discharge line does not leak, the alarm sounds and the backup only starts if the primary fails.
- Clean silt and debris from the pit, because they block the float and clog the impeller.
- If a ground-fault device is on the circuit, test it too, because it can trip and disable the pump.
- I did not find a verified service life, so the page gives none. Ask the pump maker.
Common mistakes
- Pump too small or too big
- Pit too shallow
- No check valve
- No backup
- Open or loose cover
- Discharge too close to the house
Test the sump before the rainy season. The day it matters is the day the power is out.
Heavy rain and snowmelt test the pump. Freezing can block the discharge and burn the pump out. Power outages come with storms.
Pit depth, area, cover, pump, discharge route, check valve, and the electrical.
What are the minimum pit size and cover under Part 9?
A 560 mm (22 in) round pit has a pump that switches on 200 mm (8 in) above where it switches off. How much water is pumped per cycle?
If that pump cycles every 2 minutes in a storm, what flow does it need?
A pit is 2.4 m (7 ft 10 in) below the discharge outlet, with 12 m (39 ft 4 in) of horizontal pipe. What is the rough head?
Why a check valve above the pump?
What do you test before the rainy season?
- Must-haveLayout and measuring: tape measure, marker and a level to set the pit at the lowest point and the cover flush with the slab
- Rent itPit work (machine): a concrete saw or breaker to open the slab, with wet cutting or dust extraction
- Must-havePit work (hand tools):
- Must-havePit and pump:
- Must-haveDischarge:
- Rent itElectrical (installer): a circuit installed by a licensed electrician
- Must-haveElectrical (tester): a multimeter for testing
- Must-havePPE: hard hat (CSA Z94.1), eye protection (CSA Z94.3), green-triangle boots (CSA Z195), hearing protection (CSA Z94.2), and a respirator (CSA Z94.4) with dust control when cutting concrete because of silica
Home DIY
Laborer or helper
1st-year apprentice
Apprentice, 2nd to 4th year
Journeyperson
Lead hand or foreman
Contractor or business owner
Starting a new business
The technique is the same across Canada. What changes is the code edition, the plumbing and electrical rules, the discharge rules, and the radon requirement. I read Section 9.14 in the Vancouver Building Bylaw 2014, which may not match your province's current edition. Confirm the clauses and the discharge rules with your local building department and your electrical and plumbing authorities.
See Canada by Province for the full comparison.
- Vancouver Building Bylaw 2014, Division B, Section 9.14 (9.14.4.3, 9.14.5.2; municipal reprint, edition may be older than yours)
- SupplyHouse, How to size a sump pump (a retailer's blog, US: sizing method, rules of thumb; its own examples are inconsistent, so only the method is used)
- City of Ann Arbor, Sump Pump Maintenance Checklist (municipal, US: testing, check valve, float, backup)
- Electrical and plumbing rules were not read. The old "replace every 7 to 10 years" figure is removed because I found no source. Pit, flow and head arithmetic is calculated and re-checked.
Last reviewed October 2026. General information, not engineering or legal advice.