Discharge Lines
Reviewed by a working tradesman with 17+ years in the field.
Some links on this site are affiliate links. If you buy through them we may earn a commission at no extra cost to you. Affiliate disclosure
Discharge is where drain water leaves your system. It has to go somewhere approved, and never back at the foundation.
Tap your level and the boxes below open to the advice for you. Remembered on this device.
By the end you can
- Name the places drain water may and may not go.
- Lay a solid discharge line with a check valve and a union.
- Protect the line and outlet from freezing.
- Find out what your municipality requires before you dig.
A discharge line can need a deep trench. One Canadian city's specification asks for 1.8 m (5 ft 11 in) of cover over buried lines, which makes a trench deeper than 1.2 m (4 ft). Follow the Trench Safety page and your provincial OHS regulator, and call for utility locates before you dig. Do not discharge where ice can form on a walk or street.
The big idea
Discharge is where drain water leaves the property's system. It has to go to an approved place, it must not flood a neighbour, and it must not run back to the foundation. Rules vary between municipalities, so check the local bylaw before you dig.
Where the water may go
Part 9 (Section 9.14, as printed in the Vancouver Building Bylaw 2014): foundation drains discharge to a sewer, a drainage ditch or a dry well (9.14.5.1). Where gravity drainage is not practical, an automatic sump pump does the same (9.14.5.2). A dry well is allowed only where the groundwater is below its bottom, and it must be at least 5 m (16 ft 5 in) from the foundation (9.14.5.3).
Municipal rules sit on top of that. Two Canadian municipal documents I read are examples, not your rules:
- City of Regina, Section 1350 (rev. Jan 2017): discharge to a splash pad on the surface, or to a standpipe connected to a storm service. Sanitary sewer discharge is not allowed. Surface discharge is at least 1 m (3 ft 3 in) from the building and 2 m (6 ft 7 in) from the property line, and drainage must not spill onto a sidewalk or street. External underground pipe has at least 1.8 m (5 ft 11 in) of cover. A check valve is required, with a shut-off valve downstream and a union at the pump connection.
- Town of Cobourg, Ontario: discharge outside, away from the foundation, to a ditch where one is available or to the storm sewer. No discharge to a floor drain, a laundry tub, a neighbouring property, a sidewalk or a roadway. Protect the line from freezing. It cites the Ontario Building Code and its sewer use by-law.
The distance and depth figures above are Regina's, not national. Roof water should go to its own system, not into the foundation drain. Call your municipality before you finalize the route.
Materials
- Rigid solid pipe rated for the use, to a standard your code and municipality accept. Not perforated pipe.
- Flexible hose is a temporary or seasonal measure only, and freezes and sags.
- Size the pipe for the pump's flow. Regina's spec asks for sizing to suit the pump design conditions, and a retailer's guide uses 1 1/2 in PVC unless the pump maker says otherwise.
Check valve and union
- Install the check valve above the pump, with the arrow pointing in the direction of flow. Regina's spec adds a shut-off valve downstream and a union at the pump connection, for maintenance.
- Use a serviceable valve, and test it.
Slope and routing
- Run the line to fall continuously away from the house, with no dips where water can freeze or sit. I did not find a Canadian code slope, and Regina's spec gives none, so follow your drawings and the municipality.
- Keep it away from window wells, walks and neighbours' land.
- Do not connect the sump discharge back into the foundation drain, and keep the outlet far enough from the wall that the water cannot re-enter the drain.
Example. A lot has 3 m (9 ft 10 in) between the house wall and the property line. Under Regina's distances the surface outlet must be 1 m or more from the wall and 2 m or more from the line, which needs at least 3 m. So it would fit with no margin at all, and you would look for a storm connection or another route. The lot is made up.
Freeze protection
- Bury the line below frost depth where you can. Regina asks for 1.8 m (5 ft 11 in) of cover, which is deeper than 1.2 m, so trench safety applies.
- Make sure the outlet cannot ice over or clog. Regina requires a standpipe to have a splash pad as an alternate outlet in case it freezes.
- Follow the pump maker's advice on a relief fitting where freezing is a risk.
Outlets
- Use a splash pad or erosion protection.
- Keep the outlet clear of soil, leaves and ice.
- Inspect it every season.
Common mistakes
- Discharging next to the foundation
- No check valve
- Hose used as a permanent line
- Not enough fall
- Frozen or blocked outlet
- Discharging onto a neighbour, sidewalk or street
Ask the municipality before you finalize the discharge. It is a quick call, and it avoids rework.
Freezing can block or split the line, and heavy rain increases demand. In cold areas, plan the route and outlet for winter.
Where the water goes, the routing and slope, the check valve, and freeze protection.
Under one city's specification, the line has 1.8 m (5 ft 11 in) of cover. Is the trench deeper than 1.2 m (4 ft)?
A lot has the house wall 3 m (9 ft 10 in) from the property line. One city requires surface discharge at least 1 m (3 ft 3 in) from the building and 2 m (6 ft 7 in) from the property line. Is there room?
May a sump discharge to a floor drain or the sanitary sewer?
Why a check valve and a union?
What does Part 9 allow as a discharge for a foundation drain?
It is winter, and the outlet is a flexible hose lying on the ground. What goes wrong?
- Must-haveLayout and measuring (basics):
- Nice to haveLayout and measuring (laser): a laser for long runs, to keep a steady fall
- Must-havePipe:
- Must-haveValve and fittings: a serviceable check valve, a union, and a freeze-relief fitting if the pump maker calls for one
- Must-haveDigging and backfill:
- Must-haveOutlet: a splash pad or erosion stone, and a screen or grate if the outlet needs one
- Must-havePPE:
Home DIY
Laborer or helper
1st-year apprentice
Apprentice, 2nd to 4th year
Journeyperson
Lead hand or foreman
Contractor or business owner
Starting a new business
This page is mostly local. Part 9 gives the broad rule, and the plumbing code and municipal bylaws decide where the water may go, at what distance, and at what depth. The two municipal documents I read (Regina and Cobourg) show how different the details can be. I did not check any other province, so confirm with your municipality and your provincial plumbing code.
See Canada by Province for the full comparison.
- Vancouver Building Bylaw 2014, Division B, Section 9.14 (9.14.5.1 to 9.14.5.3; municipal reprint, edition may be older than yours)
- City of Regina, Standard Construction Specification 1350, Foundation Drain Discharge System (Jan 2017, municipal: distances, 1.8 m cover, check valve, union)
- Town of Cobourg, Sump Pump Info Sheet (municipal, Ontario: no sanitary sewer, no neighbour, no sidewalk)
- SupplyHouse, How to size a sump pump (a retailer's blog, US: discharge pipe size)
- The plumbing code was not read. Distances and depths are one city's, so use them as examples only. Arithmetic is calculated and re-checked.
Last reviewed October 2026. General information, not engineering or legal advice.