Sealed Crawl Space
Reviewed by a working tradesman with 17+ years in the field.
Some links on this site are affiliate links. If you buy through them we may earn a commission at no extra cost to you. Affiliate disclosure
A sealed crawl space is part of the building. Get the water out first, then seal it by design.
Tap your level and the boxes below open to the advice for you. Remembered on this device.
By the end you can
- Explain what a sealed crawl space is and why it is a design choice.
- Say what Part 9 requires of a crawl space ground cover.
- Lay out the parts: ground cover, wall insulation, air sealing, drainage and conditioning.
- Spot the hazards of going into one.
A crawl space is a confined, low space. It can hold stale air, mould, radon, rodent droppings, sharp debris and, in older buildings, asbestos or vermiculite. Check the confined-space and hazardous-material rules with your provincial OHS regulator before you send anyone in. Never run a combustion heater or engine in there, use proper lighting, wear a respirator suited to the hazard, and never work alone.
Do not seal a space that has a furnace, water heater or other fuel-burning appliance without the design and approval of a qualified person. A blocked flue can cause carbon monoxide poisoning.
The big idea
A sealed crawl space is an unvented space treated as part of the building. Instead of venting it to the outdoors, you cover the ground, insulate the walls, seal the air leaks and keep the space dry. Done right it cuts moisture, mould, rot and heat loss. Done badly it traps moisture, so the details matter.
A Building Science Corporation article by Joseph Lstiburek (March 2020) puts the idea simply: a crawl space should be either fully connected to the conditioned house or fully separated from it, and a partial connection causes moisture problems. He calls the conditioned approach the "mini basement" and the first choice. It is written for a US audience, and the code rules differ here.
What the code says
From Part 9, Section 9.18, as printed in the Vancouver Building Bylaw 2014 (a municipal reprint, possibly older than your province's edition):
- A crawl space is treated as heated if it is used as a hot-air plenum, has heating ducts that are not sealed and insulated, or is not separated from heated space under Section 9.25 (Article 9.18.1.3).
- An unheated crawl space needs 0.1 m² of unobstructed vent area for every 50 m² of floor area, spread evenly on opposite sides of the building (Article 9.18.3.1). Heated crawl spaces must be ventilated under Section 9.32 (Article 9.18.3.2).
- Ground cover for an unheated crawl space can be 0.10 mm polyethylene with joints lapped at least 100 mm and weighted down (Article 9.18.6.1).
- For a heated crawl space, ground cover shall be not less than 0.15 mm polyethylene as part of the air barrier system, joints lapped at least 300 mm and either sealed and evenly weighted down or covered with at least 50 mm of concrete, with the perimeter sealed to the foundation wall and all penetrations sealed against air leakage (Article 9.18.6.2).
- Water entering the crawl space shall be controlled by grading or drainage, unless shown to be unnecessary (Article 9.18.5.1).
- Access openings shall be at least 500 mm by 700 mm (19 3/4 in by 27 1/2 in) for a single dwelling unit (Article 9.18.2.1).
- Insulation and other enclosing materials shall have a flame-spread rating not greater than 150 (Article 9.18.7.1).
I found no sentence there that creates a "sealed, unvented crawl space" as its own category. How one is approved in your province is a question for your building department and designer, and it depends on your edition.
The parts of a sealed crawl space
- Water out first. Sealing does not fix a wet crawl space. Get the water out and keep it out (see Drain Tile, Gravel Beds and Sump Systems), then seal.
- Ground cover: a continuous, vapour-impermeable cover that also runs across posts and piers (Building Science), at least the code minimum above, with the seams lapped and taped and run up the walls. A heavier reinforced sheet is common practice. I dropped the old 0.25 to 0.5 mm range because I could not verify it. Ask your designer for the product.
- Gravel or a drainage layer under the cover where the site is wet.
- Wall insulation: airtight rigid foam or spray foam on the foundation walls, not on the floor above, with a covering where the code requires it. Building Science recommends this for a conditioned crawl space.
- Air sealing: close the vents and seal the gaps and penetrations.
- Conditioning: the space has to be dried and kept dry. Building Science lists options, including supply air with a transfer grille to the house, a return duct, a supply fan, an exhaust fan, and a dehumidifier. It says conditioning means controlling temperature and relative humidity, and it gives no single humidity target. I dropped the old 45 to 55% target because I could not verify it, so your designer sets it. That article cites a US code rate of 50 cfm per 1,000 ft² (about 25 L/s per 100 m²) of supply air or dehumidification, which is not a Canadian rule.
- Radon: Building Science says to address soil gas with a vent under the poly, as in basements. Check your province's radon requirements.
Ground cover installation
- Lap seams at least the code lap (300 mm / 12 in for a heated space in the text I read) and tape them with a compatible tape. Follow the maker's lap if it is larger.
- Run the cover up the wall and fasten it, and seal the perimeter to the wall (Article 9.18.6.2). The height up the wall comes from your design.
- Seal around posts, pipes and piers.
- Do not tear it. Lay the sheets so people walk on it as little as possible.
Example (numbers made up). A crawl space 8 m × 10 m (26 ft 3 in × 32 ft 10 in) with the cover running 0.3 m (1 ft) up a 36 m (118 ft 1 in) perimeter needs 80 + 36 × 0.3 = about 90.8 m² (977 ft²) of poly before laps and waste. For comparison, a conventional vented space of the same area would need 0.1 ÷ 50 × 80 = 0.16 m² (1.7 ft²) of vent area under the text above.
Common mistakes
- Leaving the vents open on a space that is meant to be sealed
- Thin poly that tears
- Unsealed seams and edges
- Insulating the floor above and not the walls
- No drainage under the cover
- No drying or conditioning
- Sealing a space with a fuel-burning appliance
Sealing does not fix a wet crawl space. Get the water out and keep it out, and then seal.
Humid weather raises the moisture load. Cold weather stiffens poly and spoils tape adhesion, and rain wets surfaces before sealing. Seal on dry days, and dry the space first.
Ground cover laps and sealing, wall insulation, drainage, closed vents, and any combustion air or radon details. Confirm what your building department checks.
What does the Part 9 text I read say a heated crawl space ground cover must be?
How much vent area does a conventional unheated crawl space need in that text?
A crawl space floor is 8 m × 10 m (26 ft 3 in × 32 ft 10 in), and the cover runs 0.3 m (1 ft) up a 36 m (118 ft) perimeter wall. How much poly before laps and waste?
A crawl space is wet, with standing water. Do you seal it?
Why must a fuel-burning appliance get a design before you seal the space?
Where does the insulation go in a sealed crawl space?
- Must-haveLayout and measuring:
- Must-haveGround cover:
- Must-haveInsulation: rigid foam or spray foam as the design says, with a fire-rated covering where the code requires it
- Must-haveCutting and sealing:
- Rent itMoisture (equipment):
- Must-haveMoisture (measuring): a hygrometer to measure humidity
- Must-haveEntry: a headlamp or work lights, kneepads, and a gas or oxygen check where confined-space rules apply
- Must-havePPE:
- Must-haveRespirator: a respirator suited to the hazard (CSA Z94.4). Never work alone.
Home DIY
Laborer or helper
1st-year apprentice
Apprentice, 2nd to 4th year
Journeyperson
Lead hand or foreman
Contractor or business owner
Starting a new business
The national baseline is Part 9, Section 9.18 for crawl spaces, with 9.13.4 for radon, 9.25 for air barriers, 9.32 for ventilation and 9.36 for energy. Each province adopts its own edition, and how a sealed, unvented crawl space is accepted can differ by province and by municipality. I dropped the old per-province list because I could not verify it. Talk to your building department and get a design before you seal a crawl space.
See Canada by Province for the full comparison.
- Vancouver Building Bylaw 2014, Part 9, Section 9.18 (municipal reprint of NBC Part 9, possibly older than your province's edition: Articles 9.18.1.3, 9.18.2.1, 9.18.3, 9.18.5.1, 9.18.6, 9.18.7.1)
- Joseph Lstiburek, Insight 115: Crawlspace, Either In or Out (Building Science Corporation, March 2020; US audience, US code rates)
- Radon rules, confined-space rules by province, energy requirements for crawl space walls, and the humidity target were not verified. Poly and vent-area arithmetic is calculated and re-checked.
Last reviewed October 2026. General information, not engineering or legal advice.